FANUC SRVO-050 collision detect alarm: causes and recovery
How FANUC collision detection decides the robot hit something, why wrong payload settings make it trip when nothing did, how to recover safely, and what to check before a robot that really crashed goes back to work.
FANUC SRVO-050 is the Collision Detect alarm. The servo system decided an axis met more resistance than the move should take, stopped the robot and turned servo power off. Sometimes the robot really hit something. Sometimes the controller’s idea of what the robot is carrying is wrong, and the alarm is a false trip. This guide covers how the detection works, how to tell the two apart, how to recover safely and what to check before the robot runs again. It follows R-30iB family controllers. Your robot’s own manuals are the reference.
In short
How FANUC collision detection works
For every move, the servo system estimates a disturbance torque for each motor: the part of the load the motor is fighting that the move itself doesn’t explain. FANUC’s manual describes it as estimated from the difference between where the pulsecoder was scheduled to be and where it actually is. When the estimate on any axis passes the detection level, the controller posts SRVO-050 with the group and axis, for example SRVO-050 Collision Detect alarm (G:1,A:2), and makes a power-off stop.
There is a warning stage. SRVO-053 Disturbance excess posts when the disturbance gets close to the alarm level, and the robot keeps running. A cell that logs SRVO-053 on the same move every cycle is telling you something before it stops.
You can watch the numbers. The STATUS, Axis screen has a DISTURB page that shows each axis’s current disturbance torque and the maximum and minimum since the program or jog started, next to the allowed values. Running the suspect move and reading that page shows which axis is near its limit and in which direction.
The detection uses a model of the robot and of the load on it. That is the reason payload data matters so much.
Why do wrong payload settings cause false SRVO-050 alarms?
FANUC’s manual says plainly that wrong payload data can cause vibration and mis-detection of collisions. The controller predicts the torque each move needs from the payload settings: the mass, the center of gravity and the inertia of what is on the faceplate. If the real tool and part are heavier, or their center of gravity sits farther out than the settings say, every hard acceleration looks like the arm is being pushed. On a fast move, that is enough to trip SRVO-050 with nothing in the way.
The settings live under MENU, SYSTEM, Motion, which holds up to 10 payload schedules. Three things to check:
- The active schedule matches what’s on the robot. A gripper alone and a gripper holding a heavy part are two different payloads. The
PAYLOAD[n]program instruction switches schedules at the pick and the place. - The center of gravity and inertia are filled in, not just the mass. A long or offset tool can trip on mass and center of gravity alone, and FANUC notes that a large tool may need its inertia set too.
- Armload is set. Valve packs, cable carriers and other equipment bolted to the arm, not the faceplate, go on the armload screen.
FANUC’s Payload Identification option has the robot measure the load itself. Our FANUC payload setup guide walks through the settings in more detail.
Other causes of false trips
FANUC’s ArcTool manual, in its section on collision detection for welding torches, lists the other usual causes of a false collision detection:
- Harsh motion from a raised acceleration override (ACC).
- Sharp turnarounds on CNT moves.
- Linear moves near a singular point, where one axis has to turn very fast.
- Low supply voltage to the controller.
- A payload or inertia above what the robot is rated for.
FANUC’s mechanical manuals add cold. Near 0 degrees C, or after the robot sits idle in the cold, grease in the drive train is stiff enough to cause collision detect alarms, and FANUC recommends a warm-up program for several minutes before production.
How do you recover from SRVO-050?
-
Look before you touch
The robot stopped where it hit. Note what the tool is touching and which way it was moving. FANUC notes that position control is released briefly after a detection to limit the force, so an axis can drop slightly.
-
Make the cell safe
Follow your plant's lockout/tagout procedure before anyone enters the cell. Stay out from under the arm and the part, and out of any pinch point between the tool and the fixture.
-
Reset and jog clear in T1
Press RESET, then jog slowly in the direction that unloads the contact, usually back along the last move in the tool or user frame. Watch the part and fixture as it comes free.
-
Inspect
Check gripper fingers and fasteners, the part, the fixture, the dress pack and hoses, any camera and its bracket, and the robot's covers.
-
Check the tool center point
Move to a reference point or touch a pointer to a known mark. If the TCP has moved, fix or re-teach the tool frame before anything else runs.
-
Find out why
A changed program, a part out of position, a vision offset, a PLC handshake that let the robot in early, a fixture moved by hand. Fix that, then restart in T1 at low speed before AUTO.
When it was a real crash
A light bump that was caught early often leaves nothing to fix but the cause. A hard hit needs a closer look before production:
- Tooling. Bent fingers or a shifted gripper move the TCP, so check the tool against its drawing, not by eye. Our end-of-arm tooling page covers how we design and machine grippers in-house.
- Mastering. FANUC lists a crash that displaces a pulsecoder from its axis angle as a reason to master again. Check the robot against a reference position or its witness marks, as described in our FANUC robot mastering guide.
- Vision. If a camera on the arm or its bracket took the hit, its calibration no longer holds. Our iRVision calibration guide covers recalibrating it.
- The arm itself. New noise, vibration, grease leaks or an axis that won’t hold position point to mechanical damage inside the arm. That is work for FANUC’s service group.
Collision Guard sensitivity
FANUC’s Collision Guard software option lets the detection sensitivity be adjusted. Where it’s installed, the sensitivity is set on its setup screen and can be changed from a program for particular moves with the COL GUARD ADJUST instruction. The scale and its range depend on the software, so read your manual before changing a number.
The instructions COL DETECT OFF and COL DETECT ON switch detection off and back on between two program lines. FANUC’s advice is to correct the causes of false detection first, and only where a false trip can’t be avoided, bracket just the part of the program that causes it. Detection turns itself back on when the program ends or is paused.
Neither tool is a fix for a payload or motion problem. A less sensitive robot pushes harder before it stops. That costs grippers and parts in a real crash, and hides the next problem until it’s a bigger one. Write down any change and the reason for it.
Collision detection is there to protect the robot, the tool and the part. It is not a safety function for people. The guarding, interlocks and safety circuits do that job.
When to call
Call if the alarm keeps coming back after the payload is right, if a crash may have moved the arm or the tooling, or if nobody on site can tell which change made the robot start tripping. We work on FANUC robots other companies installed, as well as the cells we build. Call or text (818) 397-4809, or see our FANUC robot service page. The alarm text and the rest of the alarm family are covered in our FANUC alarm codes guide.
Common questions
- Can I just turn down the collision detection sensitivity?
- Not as a first step. A less sensitive setting means the robot pushes harder before it stops, which costs tooling and parts in a real crash. Fix the cause first: payload and armload data, the motion itself, a cold start. Where FANUC's Collision Guard option is installed, sensitivity can be adjusted, but change it only for a known reason, in the smallest section of program that needs it, and write the change down.
- Why does a FANUC robot post SRVO-050 on cold mornings?
- Cold grease is stiffer. FANUC's mechanical manuals say that near 0 degrees C, or after a robot sits idle in the cold over a weekend or a holiday, the extra viscous resistance in the drive train can cause collision detect alarms. FANUC recommends running a warm-up program for several minutes before production. A cell that trips only on the first cycles of the morning is a good candidate.
- Does an SRVO-050 mean the robot needs remastering?
- Not usually. A false trip or a light bump doesn't move the pulsecoders relative to the axes. FANUC lists a crash that displaces the pulsecoder from the axis angle as a reason to master again, so after a hard hit, check the robot against a reference position or its witness marks. If it's off, check the tool and the frames too, then master if the arm itself has shifted.
- What is the difference between SRVO-050 and SRVO-053?
- SRVO-053 Disturbance excess is a warning. It posts when the estimated disturbance torque gets close to the collision detection level, and the robot keeps running. SRVO-050 Collision Detect alarm posts when the level is passed, and the robot stops with servo power off. Repeated SRVO-053 warnings on the same move are an early sign of a payload or motion problem.
- Does FANUC collision detection protect people in the cell?
- No. It is there to limit damage to the robot, the tooling and the part. It reacts after contact and it isn't designed or rated as a safety function for people. Keeping people safe around an industrial robot is the job of the guarding, interlocked gates, light curtains or scanners and the safety circuits, designed from a risk assessment.
Sources
- FANUC America: Collision detection
- FANUC America: Robot support and manuals (R-30iB Operator's Manual Basic Function B-83284EN: payload setting and disturbance torque screen; Arc Welding Function B-83284EN-3: collision detection notes and COL DETECT instruction; via the Customer Resource Center)
- FANUC M-710iC/20L mechanical unit operator's manual, B-82514EN/09: SRVO-050 power-off stop and cold-weather warm-up (hosted by Haas Automation)
- FANUC Robot Safety Handbook, B-80687EN/15 (hosted by Haas Automation)