FANUC alarm codes: what the common robot alarms mean
The SRVO, MOTN and other alarms that stop FANUC robots most often, what each one means, what to check first, and how to reset it without hiding the cause. Written for maintenance techs and engineers working on R-30iB family controllers.
FANUC alarm codes are the messages a FANUC robot controller posts when it stops something or warns about something. Each one names the part of the system that raised it and a number, and FANUC’s alarm code list gives a cause and a remedy for every code. This guide covers the alarms maintenance techs hit most, grouped by what usually causes them, with the first things to check. It is written around R-30iB and R-30iB Plus controllers. Older controllers share many of the codes, but the wording and remedies can differ, so the manual for your controller wins whenever the two disagree.
In short
How to read a FANUC alarm code
A typical alarm reads SRVO-050 Collision Detect alarm (G:1,A:3). The prefix is the facility that posted it, the number identifies the alarm, and the text in brackets adds detail. On servo alarms G is the motion group and A is the axis, so this one is a collision detected on axis 3 of group 1.
The active alarm shows on the top lines of the teach pendant screen. Press MENU and select ALARM to open the alarm screen. F3 switches between active alarms and the alarm history, and F5, DETAIL shows the full text of the alarm under the cursor, its severity and any second line that explains the cause.
Read the history, not just the top line. One event often posts several alarms within the same second, and the one that explains the stop is usually the earliest of them, not the newest. Write the whole group down before anyone presses RESET.
FANUC publishes the cause and remedy for every code in the Alarm Code List manual, B-83284EN-1 for the R-30iB family. FANUC America customers can download it from the Customer Resource Center on FANUC’s support site. Keep a copy where the people who answer the line-down calls can find it.
FANUC alarm prefixes
| Prefix | What raised it | Example |
|---|---|---|
| SRVO | Servo system: amplifiers, motors, pulsecoders, brakes, and the e-stop, fence and deadman circuits | SRVO-050 Collision Detect alarm |
| MOTN | Motion planning: joint limits, singularities, positions the robot can’t reach | MOTN-023 In singularity |
| INTP | The program interpreter, while a TP program runs | INTP-224 Jump label failed |
| SYST | System state, start-up checks and system functions | SYST-223 Image backup failed |
| PRIO | I/O assignments and I/O device communication | PRIO-063 Bad I/O asg |
| HOST | Ethernet and host communication | Network and connection faults |
| FILE | Files and storage devices | FILE-077 Auto backup start |
| CVIS | iRVision | CVIS-085 Camera time out |
Alarms also differ in how hard they stop the robot. A WARN alarm, like SRVO-053 Disturbance excess, posts a message and the robot keeps running. Others pause or abort the program, and servo alarms such as SRVO-050 also turn servo power off. The detail screen shows the severity of each alarm.
E-stop, fence and deadman alarms: SRVO-001 to SRVO-007 and SRVO-037
These alarms mean a stop circuit did its job. Treat each one as two questions: who or what opened it, and is it safe to close it again.
| Alarm | What it means | First checks |
|---|---|---|
SRVO-001 Operator panel E-stop |
The e-stop button on the controller’s operator panel is pressed | Find out who pressed it and why. Twist the button to release it, then press RESET |
SRVO-002 Teach pendant E-stop |
The e-stop on the teach pendant is pressed | As above. If it won’t reset with the button released, check the pendant cable and its connector before suspecting the pendant |
SRVO-003 Deadman switch released |
The pendant is enabled and its enabling (deadman) switches are released, or gripped too hard | Hold one switch at its middle position and press RESET. If nobody is teaching, turn the pendant’s enable switch off |
SRVO-004 Fence open |
The fence or gate interlock circuit opened while the robot was in AUTO | Close the gate and reset. If the gate is shut, check the interlock switch and its wiring against the cell drawings |
SRVO-005 Robot overtravel |
The robot overtravel signal went off: an axis reached an overtravel limit switch | Jog clear using the manual’s procedure, then find out how the axis got there |
SRVO-006 Hand broken |
The hand breakage input went off, usually from a breakaway or crash sensor on the tool | Look at the tool and the sensor before moving the robot |
SRVO-007 External emergency stops |
An external e-stop input wired into the controller is open | Find which device in the cell’s e-stop circuit opened: a button, a safety relay, a safety PLC output |
SRVO-037 IMSTP input |
The *IMSTP signal, UOP input UI[1], from the PLC or peripheral interface went off |
Find out why the PLC dropped it, then check the UOP wiring or network link |
Recovery is the same for all of them. Remove the cause, release the button or close the gate, and press RESET. FANUC’s manual has e-stop buttons rotated clockwise to release them before the reset.
For SRVO-005 and SRVO-006, FANUC’s manual describes holding SHIFT, pressing the alarm release key, and jogging the tool clear while SHIFT is still held. Do it in T1 at low speed, after you have seen what the tool is touching. The alarm told you something hit or overran. Find out what before the robot runs again.
*IMSTP is a software signal. FANUC says to use the external emergency stop circuit for anything safety-critical, so SRVO-037 sends you to the PLC program, the UOP wiring or the network link rather than the hard-wired e-stop circuit.
If an alarm comes straight back after reset, the circuit is still open. Trace it with the cell’s electrical drawings, by someone qualified to work in the panel under your plant’s electrical safety rules. A stop circuit that opens for no visible reason is a switch, relay, connector or wiring fault, and jumpering it to keep running removes the protection it was put there for. Our robot cell guarding page covers how gates, interlocks and stop circuits are designed into a cell.
Collision and servo alarms
SRVO-050 Collision Detect alarm is the servo system deciding the robot hit something. For each motor it estimates a disturbance torque, the part of the load that the commanded move and the payload settings don’t explain. When that passes the detection level, the controller posts SRVO-050 and turns servo power off. Real crashes cause it. So do wrong payload settings, very cold mornings and harsh moves. SRVO-053 Disturbance excess is its warning, posted when the difference gets close to that level, and the robot keeps running.
Our SRVO-050 collision detect guide covers telling a real crash from a false trip, and how to recover from both.
SRVO-021 SRDY off is less common and harder to chase. FANUC’s alarm list describes it as the controller turning on its request for the servo amplifier’s magnetic contactor without getting the ready signal back, with no other alarm to explain it. Check the history for another alarm posted at the same moment and deal with that first. If SRDY off stands alone and repeats, it becomes a hardware diagnosis in the amplifier, the contactor and their cabling, done from FANUC’s controller maintenance manual by someone qualified to work inside the cabinet.
Battery and pulsecoder alarms
Each axis motor has a pulsecoder that tracks the motor’s position and counts its revolutions. While the controller is off, batteries in the arm keep that count. These alarms are about that count.
| Alarm | What it means | First checks |
|---|---|---|
SRVO-065 BLAL alarm |
The pulsecoder backup battery voltage is low | Replace the arm’s batteries now, with the controller powered on |
SRVO-062 BZAL alarm |
The battery voltage reached zero while the power was off, or a pulsecoder connector was unplugged. The revolution count is lost | Replace the batteries, reset the pulse coder alarm, then master the affected axes |
SRVO-075 Pulse not established |
Posted after a pulse coder reset, until the axis has moved far enough | Jog the axis until RESET clears it. FANUC’s manual says at least one motor revolution |
SRVO-068 DTERR alarm |
The controller asked a serial pulsecoder for data and got none back | Points at the pulsecoder, its cable or its connectors. FANUC’s manual says to contact FANUC for pulsecoder alarms of this kind |
BLAL is a warning you can act on. BZAL is what happens when nobody did. Programs survive a BZAL, because the controller keeps them in its own memory with its own battery, but the robot doesn’t know where its axes are until it is mastered again. The recovery is in our SRVO-062 BZAL guide, and the mastering methods are compared in our FANUC robot mastering guide.
Replacing a pulsecoder or the cable inside the arm is mechanical work on the robot. That is FANUC’s service group or a shop that rebuilds arms, and FANUC’s manuals say to contact FANUC for pulsecoder alarms like DTERR.
Motion alarms: MOTN-017 and MOTN-023
MOTN-017 Limit error means a move, or a jog, would take a joint past its software limit. Those limits are the joint operating area set at SYSTEM, Axis Limits, and the alarm names the group and the axis. Common causes are a point re-taught with a different wrist configuration or turn number, an offset or vision result that pushes the target past what that axis can reach, and a path that winds an axis toward the end of its travel. The fix is in the point or the path: re-teach with a configuration that leaves the axis room, or change how the robot approaches.
Leave the axis limits alone. FANUC’s manual says the software range can’t be extended past the factory setting, and that the mechanical stoppers should match the software limits. On a robot with Dual Check Safety, joint position checks may also be part of the cell’s safety design, set from its risk assessment, and our DCS guide covers what those checks do.
MOTN-023 In singularity means the wrist is at or near a singular point. On a typical 6-axis FANUC arm that happens when J5 is near 0 degrees, and the controller can no longer pick one joint configuration for the Cartesian position. FANUC’s manual says a linear or circular move can’t pass through a wrist singularity. It gives two ways around it: a joint move, or the wrist joint (Wjnt) motion option, which lets the wrist orientation change during the move so the tool point stays on its path. Re-teaching the point with the wrist tipped a few degrees off straight often fixes it too.
Paths that keep running into either alarm are worth checking offline. We lay out and check robot paths in FANUC ROBOGUIDE before they run on a real robot, where a limit or singularity problem shows up on the screen instead of on the floor.
Getting alarms in front of the crew
Many alarms are only seen on the pendant, which is usually hanging on the controller while the line runs. Two controller settings help get them to the PLC and the operator screen:
- Battery alarms on an output. The system variable
$BLAL_OUT.$DO_INDEXsets a digital output that turns on with BZAL or BLAL and stays on until the battery voltage is restored. The PLC can turn that into a message on the HMI while there is still time to change the batteries. - Alarm codes to the PLC. With FANUC’s error code output option loaded, alarms above WARN severity can be sent to the PLC, and the Error Severity Table (MENU, SETUP, Error Table) can raise chosen alarms to a higher severity.
How a cell shows its faults is a design decision. On the operator screens we write, fault status is shown in words the crew uses, not just the code.
How to reset a FANUC alarm
-
Read the history
Open MENU, ALARM and find the first alarm posted when the robot stopped. Write down the full text, including the detail line.
-
Make the cell safe
Put the robot in a safe state and follow your plant's lockout/tagout procedure before anyone goes into the cell.
-
Fix the cause
Release the e-stop, close the gate, clear the jam or correct the point. A reset without a fix only posts the alarm again.
-
Press RESET
Reset from the teach pendant or the operator panel. Some alarms need more: after a pulse coder reset for SRVO-062, the controller has to be power cycled.
-
Restart slowly
After a crash, a remaster or a program change, run the next cycle in T1 at low speed and watch it before going back to AUTO.
When to stop and call
Some alarms are a five-minute fix. These are the ones where we’d stop and get help:
- The same alarm comes back after reset and you can’t find the cause.
- A pulsecoder alarm other than low battery: DTERR, CRCERR, PHAL and the others FANUC lists under pulsecoder trouble.
- The robot hit something hard enough to move the tooling, the fixture or the arm.
- Clearing a stop alarm would mean defeating a gate switch, a light curtain or an e-stop.
- A BZAL on a robot with no quick mastering reference position and no witness marks you trust.
- There is no current backup of the controller. Our FANUC robot backup guide covers what to save.
We work on FANUC robots other companies installed, as well as the cells we build in Fontana, CA. Call or text (818) 397-4809 with the robot and controller model, the alarm text from the history and a photo of the pendant screen. What that kind of job looks like is on our FANUC robot service page, and the way we write and fix robot programs is on FANUC robot programming.
Common questions
- How do I reset a FANUC robot alarm?
- Find and fix the cause first, then press RESET on the teach pendant or the operator panel. For an e-stop, twist the button to release it before pressing RESET. If the alarm posts again straight away, the cause is still there. A few alarms need more than RESET: after a pulse coder reset for SRVO-062 BZAL, for example, the controller has to be power cycled and the robot mastered.
- Where is the alarm history on a FANUC teach pendant?
- Press MENU and select ALARM. The screen shows active alarms, and F3 switches between active alarms and the alarm history. Move the cursor to an alarm and press F5, DETAIL to see its full text, the severity and any second line that explains the cause. Look for the earliest alarm posted when the robot stopped, because one event often posts several.
- What does SRVO mean in a FANUC alarm?
- SRVO is the facility code for the servo system. SRVO alarms come from the amplifiers, motors, pulsecoders and brakes, and from the stop circuits the servo system watches: e-stops, the fence circuit and the teach pendant deadman switches. SRVO-001 to SRVO-007, SRVO-050 collision detect and the SRVO-062 and SRVO-065 battery alarms are all in this family.
- Why does a FANUC alarm come back right after I reset it?
- Because whatever caused it is still true. An e-stop circuit is still open somewhere, the gate switch isn't made, the PLC is still holding a stop input off, or the robot is still pressed against something. Go back to the alarm history and the detail screen, find the first alarm in the group, and trace that cause before resetting again. Never jumper a safety input to make an alarm clear.
- Is there a complete FANUC alarm code list?
- Yes. FANUC publishes the cause and remedy for every code in the controller's Alarm Code List manual, which is B-83284EN-1 for the R-30iB family. FANUC America customers can download manuals from the Customer Resource Center on FANUC's support site. Use the edition that matches your controller and software, because older controllers share many codes but not always the same wording or remedy.
- Can CalWest help with an alarm on a FANUC robot it didn't install?
- Yes. We service and reprogram FANUC robots other companies installed, as well as the cells we build. Call or text (818) 397-4809 with the robot and controller model, the alarm text from the history and a photo of the pendant screen. If the fault points to a part inside the arm, such as a pulsecoder or reducer, we'll tell you plainly that FANUC's service group is the place for that part.
Sources
- FANUC America: Robot support and manuals (R-30iB Operator's Manual Basic Function B-83284EN and Alarm Code List B-83284EN-1, via the Customer Resource Center)
- FANUC Robot Safety Handbook, B-80687EN/15 (FANUC America, hosted by Haas Automation)
- FANUC M-710iC/20L mechanical unit operator's manual, B-82514EN/09: mastering and battery alarms (hosted by Haas Automation)
- FANUC America: Collision detection
- FANUC Tech Transfer: FANUC Changing Batteries