FANUC SRVO-062 BZAL alarm: batteries, pulse reset and mastering
What the battery zero alarm means, how SRVO-065 BLAL warns you first, how to change the arm's pulsecoder batteries without losing position, and the steps from BZAL back to a mastered robot.
FANUC SRVO-062 is the BZAL alarm: the backup battery voltage for a pulsecoder reached zero, and that axis has lost its revolution count. The robot’s programs are fine, but the controller no longer knows where the affected axes are, so the robot has to be mastered before it runs again. This guide covers what causes it, how to change the batteries so it doesn’t happen, and the recovery steps a maintenance tech can follow. Menu names here are from R-30iB and R-30iB Plus controllers. Your robot’s mechanical unit manual and controller manual are the reference for your model.
In short
What causes the SRVO-062 BZAL alarm?
Every axis motor has a pulsecoder. It reports two things: the position within one motor revolution, and how many revolutions the motor has turned. The controller powers the pulsecoders while it is on. When it is off, a set of batteries in the arm keeps the revolution counts alive.
BZAL is posted when that battery voltage reaches zero while the power is off. FANUC’s manuals give the usual causes:
- The batteries ran down, often on a robot left unpowered for a long time.
- A pulsecoder connector was unplugged, for example during a cable replacement, which drops that pulsecoder’s voltage to zero.
- A broken cable cut one axis off from the batteries, which gives BZAL on that axis alone.
What survives is the position within one revolution. What is lost is the count of revolutions. That is why the fast recovery, quick mastering, works: as long as each axis is put back within half a motor revolution of a known position, the controller can work out the rest.
SRVO-065 BLAL is the warning
SRVO-065 BLAL alarm comes first. It means the pulsecoder battery voltage has dropped low, and FANUC’s instruction is to replace the batteries immediately while keeping the power on. If BLAL is reset and ignored, the batteries keep draining, and a shutdown for a holiday or a move can be all it takes to reach BZAL.
If nobody watches the pendant, put the warning where people will see it. The system variable $BLAL_OUT.$DO_INDEX assigns a digital output that turns on with BLAL or BZAL and stays on until the battery voltage is restored, and the PLC can show it on the operator screen. More on getting alarms to the crew is in our FANUC alarm codes guide.
How do you replace FANUC pulsecoder batteries?
The battery case is on the arm, often on the base, and holds a set of ordinary dry cells. The M-710iC manual we checked calls for four 1.5 V size D cells. Check your robot’s mechanical unit manual for the location and part number before you start, and take a fresh backup: our FANUC robot backup guide covers the All of above and image backups FANUC recommends before this job.
-
Take a backup
Save an All of above backup and an image backup first, as FANUC's own battery procedure recommends.
-
Leave the controller on
The controller must stay powered for the whole job. Replacing the batteries with the power off loses the position data.
-
Press the e-stop
Press the emergency stop so the robot can't move. You will be working next to a powered robot, so follow your plant's procedure for work on energized equipment.
-
Swap the whole set
Remove the battery case cap, take out every old cell and fit new ones, watching the polarity marked on the case.
-
Close it up
Refit the cap. On robots with the severe dust and liquid protection option, FANUC says to fit a new gasket on the battery cover.
-
Clear the warning
Release the e-stop, reset, and check that no BLAL or BZAL alarm comes back.
FANUC’s mechanical manuals list the batteries as a periodic replacement item. The M-710iC manual says every 1.5 years, and FANUC’s Tech Transfer recommends once a year. Use the interval in your own robot’s manual, and replace them before a robot is unplugged for a move or long storage. FANUC’s safety handbook also asks that spent robot batteries be disposed of properly, since a shorted battery can start a fire.
The controller has a separate battery on its main board that keeps programs, settings and mastering data. Its replacement is in the controller maintenance manual, and a backup before that job matters even more.
How do you clear SRVO-062 and SRVO-075?
If BZAL has already happened, replace the batteries first, then follow FANUC’s reset procedure.
-
Open Master/Cal
Press MENU, select 0 NEXT, then 6 SYSTEM. Press F1, TYPE and select Master/Cal. If it isn't on the list, set the system variable $MASTER_ENB to 1 on the SYSTEM, Variables screen.
-
Reset the pulse coder alarm
Press F3, RES_PCA, then F4, YES.
-
Cycle the controller power
SRVO-062 should be gone. SRVO-075 Pulse not established will still be posted for the affected axes.
-
Jog each affected axis
In T1, jog the axis in either direction and press RESET until SRVO-075 clears. FANUC's manual says it clears once the motor has turned at least one revolution.
Keep those jogs small and slow. Until the axis is mastered, the position the controller shows is wrong, and FANUC warns that moving an unmastered robot too far can take it past its real motion limits and damage the arm or its cables. Move only as much as it takes to clear SRVO-075, unless the mastering method needs the axis somewhere else.
Which mastering method after a BZAL?
Nothing mechanical changed, so one of the quick methods usually applies. Full details are in our FANUC robot mastering guide.
| Situation | Method |
|---|---|
| A quick mastering reference position was set, and the axes can be jogged back to it within half a motor revolution | Quick master, master at reference position |
| R-30iB Plus at software V9.40P/62 or later, and the arm didn’t move while the power was off | Quick master, master using power off position |
| BZAL on one or two axes only | Quick master for single axis, at the reference position |
| No reference position was ever set, or it can’t be trusted | Zero position mastering on the witness marks, as a temporary fix |
Quick mastering is not valid after a pulsecoder, motor, reducer or arm has been replaced, and FANUC says the power off position mode shouldn’t be used on a robot that was just installed or moved, since shipping can shift the axes. Mastering data entry, which types in recorded mastering values, doesn’t help here either: FANUC says it can’t be used once the pulse counts are lost.
After mastering, select 7 CALIBRATE and press F4, YES, then F5, DONE, which sets $MASTER_ENB back to 0.
Before the robot goes back into production
- Check the mastering. FANUC’s manual suggests running to a known point in a program and checking it lands where it should, or setting all axes to zero and checking the witness marks line up.
- If the controller has Dual Check Safety, apply and verify the DCS parameters after mastering. FANUC’s own mastering procedures include this step, and our DCS guide explains what those settings protect.
- Step through the program in T1 at low speed before AUTO.
- Take a new backup, so the new mastering data is saved off the robot.
If any of this doesn’t add up, stop. Positions that are off by a consistent amount after mastering, a BZAL that returns with new batteries, or one axis that keeps losing its count points to a cable or pulsecoder, which is mechanical work for FANUC’s service group. For the robot side, the backup, the mastering check and the program work, call or text (818) 397-4809. We work on FANUC robots we didn’t build, and our FANUC robot service page describes how a job starts.
Common questions
- Does replacing the batteries clear SRVO-062 BZAL?
- No. New batteries stop it from happening again, but the revolution count the pulsecoder lost is gone. You still reset the pulse coder alarm on the Master/Cal screen with RES_PCA, cycle the controller power, jog each affected axis until SRVO-075 Pulse not established clears, then master those axes and run CALIBRATE before the robot is used again.
- Does a BZAL alarm erase the robot's programs?
- No. Programs, registers and settings live in the controller's memory, which has its own backup battery. BZAL means the arm's pulsecoders lost their revolution counts, so the controller no longer knows where those axes are. The programs are intact, but every point would be off until the robot is mastered again.
- How often should FANUC robot batteries be replaced?
- Use the interval in your robot's mechanical unit manual. The M-710iC manual we checked lists them as a 1.5-year item, and FANUC's Tech Transfer recommends replacing them once a year. Replace them sooner if SRVO-065 BLAL appears, and before a robot is unplugged for a move or long storage, since that is when the batteries are doing all the work.
- Why do FANUC batteries have to be changed with the power on?
- While the controller is powered, it supplies the pulsecoders, and the batteries are only needed when the power is off. FANUC's manuals warn that replacing the batteries with the power off loses all current position data, which means mastering the robot again. Keep the controller on and press the e-stop so the robot can't move.
- Can I use quick mastering after a BZAL alarm?
- Usually, if nothing mechanical was changed. Quick mastering works because the pulsecoder keeps its position within one motor revolution even when the revolution count is lost. It is not valid after a pulsecoder, motor, reducer or arm replacement, and the axis has to be within half a motor revolution of the reference position when you run it.
Sources
- FANUC M-710iC/20L mechanical unit operator's manual, B-82514EN/09: replacing the batteries, mastering, BZAL and BLAL (hosted by Haas Automation)
- FANUC America: Robot support and manuals (R-30iB Operator's Manual Basic Function B-83284EN, appendix B.2 Mastering, via the Customer Resource Center)
- FANUC Tech Transfer: How to replace batteries on an industrial robot
- FANUC Tech Transfer: FANUC Changing Batteries
- FANUC Tech Transfer: Quick mastering on R-30iB Plus using power off position
- FANUC Robot Safety Handbook, B-80687EN/15 (hosted by Haas Automation)