CalWest ManufacturingRobotics Fontana, CA

Call or text (818) 397-4809

FANUC SRVO-021 SRDY off: when servo power won't come on

What the servo ready signal is, why SRVO-021 means the amplifier's contactor didn't close for no reason the controller could name, the ordinary causes to rule out first, and the checks FANUC lists before parts get replaced.

FANUC SRVO-021 is the SRDY off alarm. The controller asked the servo amplifier to close its magnetic contactor, the MCC that switches power to the motors, and the servo ready signal never came back. It is an unusual alarm, because FANUC only posts it when no other alarm explains the problem. Most of the time servo power stays off for an ordinary reason with its own alarm, so this guide starts there, then covers what SRVO-021 means and the checks FANUC lists before parts are replaced. It follows R-30iB family controllers, with connector names from the R-30iB Mate maintenance manual.

In short

SRVO-021 SRDY off means the controller turned on HRDY, its request to close the servo amplifier’s magnetic contactor, and SRDY, the signal that the contactor is on, didn’t come back, with no other alarm to explain it. Rule out e-stop, fence, deadman and IMSTP alarms first. Then FANUC’s checks are the connectors between the emergency stop unit and the amplifier, a power interruption, the emergency stop unit and the amplifier.

What do SRDY and HRDY mean?

FANUC’s maintenance manual gives two signals. HRDY is the controller, the host, telling the servo system to turn the servo amplifier’s magnetic contactor on or off. SRDY is the servo system telling the host whether the contactor actually turned on. Put together, turning servo power on is a handshake: the controller raises HRDY, the contactor closes, and SRDY confirms it.

SRVO-021 is posted when HRDY is on and SRDY is off although there is no other cause of an alarm. FANUC’s explanation adds the important part: if the contactor fails to close because of a servo amplifier alarm, the controller posts that alarm instead. So SRVO-021 means the contactor didn’t close for a reason the controller couldn’t identify. The alarm reads like SRVO-021 SRDY off (Group:1 Axis:1).

Why servo power won’t come on: rule these out first

A robot with no servo power and SRVO-021 in the history is a different problem from a robot that simply won’t take a reset. Before chasing SRDY, look for these:

What you see What usually holds servo power off
SRVO-001, -002 or -007 An e-stop button or the external e-stop circuit is open
SRVO-003 The pendant is enabled and the deadman isn’t held at its middle position
SRVO-004 The fence circuit is open in AUTO
SRVO-037 The PLC or its wiring has the *IMSTP input off
SRVO-230 to SRVO-275 chain alarms A dual-channel safety input disagreed, and the chain error hasn’t been reset
Any other active alarm RESET hasn’t cleared it, so the controller won’t turn servo power on

The STATUS, Stop Signal screen (MENU, 0 NEXT, 4 STATUS, F1 TYPE, Stop Signal) shows which stop inputs are active. Our SRVO-007 external e-stop guide covers the e-stop, fence and chain alarms, and the SRVO-037 IMSTP guide covers the PLC’s stop input.

FANUC’s manual says the RESET signal cancels an alarm and, if servo power is off, turns it on. For the PLC, UO[2] SYSRDY is on while servo power is on. If RESET leaves SYSRDY off and SRVO-021 posts, you are in the right guide.

What FANUC says to check for SRVO-021

The R-30iB Mate maintenance manual lists these actions in order. Other cabinets use different connector names, and the R-30iB and R-30iB Plus maintenance manual, B-83195EN, has theirs.

  1. Read the history

    Open MENU, ALARM, F3 HIST and look for anything posted at the same moment, especially servo amplifier, fuse or DCS alarms. If one is there, it comes first.

  2. Check the connectors

    With power off and locked out, make sure the emergency stop board connectors CP5A, CRMA92 and CRMB22 and the amplifier connector CRMA91 are fully seated. With an auxiliary axis amplifier, also check CXA2A and CXA2B.

  3. Check for a power interruption

    FANUC lists an instant disconnection of the power source as a possible cause. Look at what else happened on the plant's supply at that time.

  4. Replace the emergency stop unit

    On the Mate, the magnetic contactor is part of the E-stop unit, and replacing it is FANUC's next action.

  5. Replace the servo amplifier

    The last action on FANUC's list, after a full backup.

Note the order. FANUC puts two inspection steps and a supply check ahead of any part, and both parts are expensive. A connector that worked loose during a move or a panel job, or a supply that dips when a large machine starts, is a much cheaper answer.

Alarm What FANUC’s manual says FANUC’s action
SRVO-022 SRDY on When HRDY is about to go on, SRDY is already on Replace the servo amplifier
SRVO-349 DCS MCC ON alarm A command was issued to turn the magnetic contactor on, but it did not turn on Replace the E-stop unit, which includes the contactor, then the main board, then the amplifier
SRVO-348 DCS MCC OFF alarm A command was issued to turn the magnetic contactor off, but it did not turn off Check any device connected to the E-stop unit’s CRMB8 and that CRMB16 is seated, then replace the E-stop unit

These two carry the DCS prefix: the controller’s safety software checks that the contactor really followed its command, and they are how a contactor that won’t close, or won’t open, shows up. A contactor that won’t open is the more serious of the two, because it is part of how the robot loses power when it is told to stop. Don’t try to keep a robot running with SRVO-348. Get it fixed first.

Watching servo ready on the pendant

The axis status screens show what the servo system reports. Open MENU, 0 NEXT, 4 STATUS, F1 TYPE, Axis, then STATUS1. FANUC’s table for that page lists a servo ready bit, SRDY, for each axis, next to the overcurrent and disconnection bits, with a history field beside the live value. A photo of that page, taken when the alarm is posted, is worth sending with any service call.

For the operator screen, UO[2] SYSRDY is the signal to use. An HMI that shows when servo power is off, with the robot’s active alarm next to it, tells the crew where to look before anyone opens a cabinet.

When to call

Call when SRVO-021 keeps returning after the connectors are checked, when it lines up with nothing you can find on the supply, or when any of the DCS MCC alarms posts. Replacing a contactor, an E-stop unit or an amplifier is controller hardware work for FANUC’s service group or someone trained on that cabinet. We work on FANUC robots other companies installed as well as the cells we build in Fontana, CA, and we can help sort the alarm history, the stop circuits and the PLC side before parts are ordered. Call or text (818) 397-4809 with the robot and controller model, the alarm history and a photo of the STATUS1 page. What a service job looks like is on our FANUC robot service page, the other common alarms are in our FANUC alarm codes guide, and the UOP conditions that keep a robot from starting are in our robot won’t run in auto guide.

Common questions

What does SRDY mean on a FANUC robot?
SRDY is the servo ready signal. FANUC's maintenance manual describes it as the signal the servo system uses to tell the controller whether the servo amplifier's magnetic contactor is on. Its partner, HRDY, is the controller's request to turn the contactor on. SRVO-021 SRDY off means HRDY was on but SRDY never came back, with no other alarm to explain it.
Is SRVO-021 the same as an e-stop alarm?
No. An open e-stop, fence or deadman circuit posts its own alarm, such as SRVO-001, SRVO-004 or SRVO-007, and servo power stays off until that circuit is closed and reset. FANUC's manual says SRVO-021 is posted when no other cause of an alarm is found, so it means the contactor didn't close for a reason the controller couldn't name.
Can a power dip cause SRVO-021?
Yes. FANUC's maintenance manual lists an instant disconnection of the power source as a possible cause and says to check whether one occurred. If SRVO-021 lines up with large equipment starting elsewhere in the plant, storms or utility work, have an electrician look at the supply to the robot controller before replacing parts.
How do I know servo power is on?
On the pendant, the robot jogs and programs run with no servo alarm posted. For the PLC, the peripheral output UO[2] SYSRDY is on while servo power is on, which is the signal most cells use to show it on the operator screen. For diagnosis, the STATUS, Axis screens show a servo ready bit for each axis.
Should I replace the servo amplifier for SRVO-021?
Only after the ordinary causes and FANUC's first checks are done. The maintenance manual's list for SRVO-021 starts with making sure the connectors between the emergency stop unit and the servo amplifier are seated, then checking for a power interruption, then replacing the emergency stop unit, and only then the servo amplifier. Take a full backup before any board or amplifier work.

Sources

  1. FANUC R-30iB Mate/R-30iB Mate Plus controller maintenance manual, B-83525EN/07: troubleshooting SRVO-021, SRVO-022, SRVO-348 and SRVO-349, stop signals screen (hosted by Haas Automation)
  2. FANUC R-30iB/R-30iB Plus controller operator's manual (Basic Function), B-83284EN/10: peripheral I/O (RESET, SYSRDY) and B.4 robot axis status (hosted by RoboChallenge)
  3. FANUC America: Robot support and manuals (Alarm Code List B-83284EN-1 and R-30iB/R-30iB Plus maintenance manual B-83195EN, via the Customer Resource Center)

Start a project

Bring us the process. We'll bring the cell.

Send a phone video of the manual process, or a part drawing, by text or email. We come back with a cell concept and a plan: robot, tooling, controls and code.

Call or text
Call or text
(818) 397-4809
Email
sales@calwestmfg.com
Shop
13815 Arrow Rte, Fontana, CA 92335
Hours
Mon–Fri 7:00am – 3:45pm

FANUC Authorized System Integrator (ASI). Part of CalWest Manufacturing, founded 2012: AS9100D and ISO 9001 certified, ITAR registered.