FANUC robot maintenance schedule: daily checks, batteries and grease
What FANUC's own manuals say to check every day, every few months and every few years, with the battery and grease intervals for three common models, and why your robot's manual and its hours decide the real schedule.
A FANUC robot maintenance schedule isn’t one list for every robot. FANUC publishes it per model, in the checks and maintenance chapter and the periodic maintenance table of each mechanical unit manual, and the intervals differ from model to model and with the options fitted. This guide pulls together what three of those manuals say, for the LR Mate 200iD, the M-20iD and the M-710iC/20L, plus the R-30iB Mate controller manual, so you can see the pattern and know what to look up for your own robot. Treat the numbers here as examples. Your robot’s manual, and the hours it actually runs, set the real schedule.
In short
The intervals assume 3,840 hours a year
All three manuals give each interval as a period or as accumulated operating time, whichever comes first, and all three state the same assumption: the robot runs up to 3,840 hours a year. Above that, FANUC says to scale every interval by the ratio of your hours. A robot running 7,680 hours a year needs maintenance twice as often, so a 3-year grease change becomes 1.5 years. A robot on two or three shifts can pass 3,840 hours well before the calendar says it’s due, so track hours, not just dates.
The schedule also changes with duty. FANUC’s manuals note that frequent repetitive motion and high temperatures raise the pressure in the grease baths, and that shows up as seepage at the seals in the daily checks.
Daily checks
FANUC’s daily list is short, and it is the same idea on every model in these manuals. Do it before the shift starts, from outside the cell where you can:
Daily, per FANUC's mechanical unit manuals
- Oil seepage at the sealed part of each joint. Wipe it off, and note which joint
- The air control set, if fitted: pressure, lubricator drip rate and drain
- Vibration or abnormal noise
- Positioning: taught positions haven't drifted from where they were
- Peripheral equipment responding properly to the robot's commands
- Brakes: how far the end effector drops when servo power turns off
- Unexpected warnings on the alarm screen
The brake check has a number. FANUC’s limits for the end effector drop at servo power off are 2 mm for the LR Mate 200iD, 5 mm for the M-20iD and 0.5 mm for the M-710iC/20L. A robot that drops more than that is sent to the manual’s troubleshooting section under dropping axis. Keep people out from under the arm until it has been looked at.
On the controller, the R-30iB Mate manual adds checking the pendant cable for excessive twisting before work, and cleaning the ventilation port at the end of the day if it is dusty.
Periodic checks
The periodic tables in these manuals follow a common pattern:
| Interval | What FANUC lists |
|---|---|
| Every 3 months (960 h) | External damage or peeling paint from contact with other equipment; water or cutting fluid on the robot; cleaning the controller ventilation, first checked at 1 month |
| Yearly (3,840 h), first checked at 3 months | Teach pendant and robot connection cables; end effector cable; exposed motor and other connectors; end effector mounting bolts; base and cover bolts; mechanical stoppers; spatter, sawdust and dust |
| By model | Mechanical unit batteries, grease or oil, mechanical unit cable, controller batteries (see the next table) |
A few of those checks have details that matter. Circular connectors are checked by turning them by hand, square ones by their locking lever, and earth terminals for tightness. Bolts are retightened to the torque table at the back of the manual and no higher, because FANUC notes some bolts carry thread-locking adhesive that over-torquing can break. A mechanical stopper that shows the mark of a hit gets replaced, and on the LR Mate the J1 and J3 stopper spring pins are replaced if they’re bent. A stopper hit also means the robot crashed, which is worth understanding; our SRVO-050 collision guide covers that alarm.
Battery and grease intervals by model
| LR Mate 200iD | M-20iD/25 | M-710iC/20L | |
|---|---|---|---|
| Manual | B-83494EN/06 | B-84074EN/03 | B-82514EN/09 |
| Pulsecoder batteries in the arm | 1 year built-in, 1.5 years with the external battery box | 1 year, whatever the hours | 1.5 years |
| Reducer lubrication | Grease top-up every 4 years or 15,360 h; 2 years or 7,680 h on 7C/7LC | Replace J1 to J3 grease and J4 to J6 gearbox oil every 3 years or 11,520 h | Replace J1 to J3 reducer and J4, J5 gearbox grease every 3 years or 11,520 h; grease J6 yearly or every 3,840 h |
| Mechanical unit cable | Replace at 4 years | Replace at 4 years; welding power cable and M/H conduit options at 2 years | Replace at 4 years |
| Controller batteries | 4 years | 4 years | 4 years |
| Brake drop limit | 2 mm | 5 mm | 0.5 mm |
For cable replacement, the manuals say to contact FANUC. Other models, and other variants of these, have their own tables.
Replacing the batteries
The batteries in the arm keep each pulsecoder’s position count while the controller is off. FANUC’s procedure on all three models is to press the emergency stop and leave the controller powered on while the batteries are changed. Replacing them with the power off loses the position data, and the robot then has to be mastered. FANUC’s Tech Transfer video on the job calls that one of the most common mistakes, and asks for an All of above backup and an image backup before starting.
Change them at the interval, or sooner when the low battery warning appears. Don’t wait for it to become the SRVO-062 BZAL alarm. Our BZAL guide covers what happens then, and the mastering guide covers the recovery.
The controller’s memory battery is a different job. On the R-30iB Mate, it is a lithium battery that keeps the programs and system variables in memory for about 4 years. Its low voltage alarm is SYST-035. FANUC’s procedure is the reverse of the arm batteries: turn the controller on for about 30 seconds, turn it off, and swap the battery unit within 30 minutes. Take a backup before you start. R-30iB A and B cabinets are covered by their own maintenance manual, B-83195EN, so check yours.
Replacing grease and oil
Grease replacement is where a careful job and a rushed one end up far apart. FANUC’s cautions in these manuals include:
- Lock out the robot per your plant’s procedure for the hands-on part. FANUC’s steps turn the controller off after the robot is moved to the greasing posture the manual gives for each axis.
- Open the grease outlet before you pump, so old grease has somewhere to go.
- Pump slowly by hand, about one stroke every two seconds. Avoid pumps driven by shop air, or keep their gun tip pressure at or below the 0.1 MPa the manuals give.
- Use only the specified grease or oil. The M-20iD and M-710iC reducers take Kyodo Yushi VIGOGREASE RE0, and the LR Mate 200iD manual says not to use Harmonic Grease SK-3 in place of its specified grease.
- Release the pressure afterward. On the M-710iC’s J1 to J4 axes that means running the axis, with the inlet and outlet open, for at least 20 minutes at the motion the table gives, with everyone outside the guarding.
- Hot grease can spray when an outlet is opened. FANUC lists heat-resistant gloves, eye and face protection and bags to catch it.
Too much pressure in a grease bath breaks the seal, and the manuals say that leads to leaks and abnormal operation. The LR Mate is a top-up by syringe with a measured amount per axis, not a flush, and the manual says not to exceed it.
Cables, dress packs and controller fans
The mechanical unit cable inside the arm is checked at its moving sections for worn jackets, excessive bending and uneven twisting, and it is replaced at the interval in the table. The end effector cable and hoses, the dress pack your integrator added, get the same check: look where they rub, where clamps hold them and where they flex every cycle.
For the controller, the R-30iB Mate manual says to check after the first month that the fans are turning, and every six months to clean the dust out of the cabinet and off the fans. The mechanical manuals add cleaning the controller ventilation every 3 months. A controller on a dusty floor may need it more often.
Back up before any PM
Take an All of above backup and an image backup before maintenance starts, and copy them off the robot. Our FANUC robot backup guide shows how. After the work, run a reference check, step the program in T1 at low speed, and take another backup.
Mechanical work inside the arm, such as reducers, motors and pulsecoders, is usually a job for FANUC’s own service group. We work on the robot side and the cell around it: programs, I/O, tooling, backups and the checks after a battery or mastering job, on FANUC robots other companies installed as well as our own. See our FANUC robot service page, or call or text (818) 397-4809.
Common questions
- How often should FANUC robot batteries be replaced?
- It depends on the model and the battery type. FANUC's manuals give 1 year for the M-20iD, 1 year for an LR Mate 200iD with built-in batteries and 1.5 years with the external battery box, and 1.5 years for the M-710iC/20L. Replace them sooner if the low battery alarm appears, always with the controller powered on, and take a backup first.
- How often does a FANUC robot need grease?
- Again by model. The M-710iC/20L and M-20iD manuals call for replacing the reducer grease, and on the M-20iD the wrist gearbox oil, every 3 years or 11,520 hours. The LR Mate 200iD gets a measured top-up every 4 years or 15,360 hours, or every 2 years on the 7C and 7LC versions. Use only the grease or oil the manual specifies.
- Do FANUC maintenance intervals change with more shifts?
- Yes. FANUC writes its periodic maintenance for up to 3,840 operating hours a year and says to scale the intervals by the ratio of your actual hours. A robot running 7,680 hours a year needs its maintenance twice as often, so a 3-year grease interval becomes 1.5 years. Every interval is also given in hours, and whichever comes first applies.
- Should the controller be on or off when replacing FANUC batteries?
- It depends which battery. The batteries in the arm that hold the pulsecoder counts are replaced with the controller on and the e-stop pressed, because replacing them with power off loses the position data and the robot needs mastering. The R-30iB Mate's memory battery on the main board is replaced with the controller off, within 30 minutes, after it has been on for about 30 seconds.
- What should a FANUC robot PM checklist include?
- Backups first. Then the daily items done carefully: oil seepage, noise, positioning, brake drop and warnings. Then cables, connectors, end effector and base bolts, mechanical stoppers, spatter and dust, controller fans and ventilation, the batteries if they're due, and the grease or oil when the hours call for it. Work from the periodic maintenance table in your robot's own manual.
Sources
- FANUC LR Mate 200iD / ARC Mate 50iD mechanical unit operator's manual, B-83494EN/06: chapter 7 Checks and maintenance, appendix A periodic maintenance table (hosted by Haas Automation)
- FANUC ARC Mate 120iD / M-20iD mechanical unit operator's manual, B-84074EN/03: chapter 7 Checks and maintenance (hosted by Haas Automation)
- FANUC M-710iC/20L/12L/20M mechanical unit operator's manual, B-82514EN/09: chapter 7 Checks and maintenance, appendix A periodic maintenance table (hosted by Haas Automation)
- FANUC R-30iB Mate/R-30iB Mate Plus controller maintenance manual, B-83525EN/07: 2.3 Checks and maintenance, 8.9 to 8.11 fans and battery (hosted by Haas Automation)
- FANUC Tech Transfer: How to replace batteries on an industrial robot
- FANUC America: Robot support and manuals (Customer Resource Center)
- OSHA 29 CFR 1910.147: The control of hazardous energy (lockout/tagout)