A robotics glossary of robot cell and FANUC terms
Plain definitions of the words that show up in a robot cell quote and at a FANUC teach pendant, written by the team that builds and programs our cells in Fontana.
Project and safety terms come first, since they show up in quotes and schedules. Robot and tooling terms follow, then the FANUC programming, vision and controls terms your maintenance team will use. Where a term has a longer page in our guides and resources, the definition links to it.
Abbreviations you’ll see on a robot cell quote
| Short form | Stands for |
|---|---|
| EOAT | End-of-arm tooling, the gripper or tool on the robot’s wrist |
| FAT, SAT | Factory acceptance test, site acceptance test |
| TCP | Tool center point, the working point of the tool |
| UFRAME, UTOOL | User frame and tool frame, in FANUC’s naming |
| DCS | Dual Check Safety, FANUC’s position and speed monitoring |
| PLC, HMI | Programmable logic controller, human-machine interface |
| LOTO | Lockout/tagout |
Buyer and project terms
Robot cell
A robot, its tooling, and everything around it needed to do one job: base or frame, guarding, part feeding, sensors, control panel and programs. Our robot cell design page shows how we model and prove a whole cell in SolidWorks.
Robot integrator
The company that turns a robot into a working cell. The robot maker supplies the arm, controller and teach pendant, and the integrator designs, builds, programs and installs everything else. Our guide on how to choose a robot integrator lists the questions that show who does each piece.
Turnkey cell
A cell delivered ready to run, with one supplier answerable for the design, build, programming, install and commissioning. Some suppliers also use the word for pre-engineered catalog cells, so ask which kind they mean, and read the scope either way: rigging, utilities, floor work and the signals to your existing machines are common exclusions. Our turnkey robot cells page shows what ours include, and the robot cell cost breakdown lists the lines a complete quote should cover.
Cycle time and takt time
Cycle time is how long the cell takes to finish one part, measured the way the spec says. Takt time is the pace your demand sets: available production time divided by the parts needed in that time. A cell has to beat takt with room left for faults and changeovers.
Changeover
Switching the cell from one product to the next: a different program or pattern, new fingers, another fixture. How long it takes, and who may do it, belongs in the spec. On the LR Mate assembly cells we built for a national lawn and garden brand, color changeover status is shown on the operator screen.
Run-off and factory acceptance test (FAT)
The run-off is the first time the finished cell runs as a whole in the builder’s shop. The FAT is the formal version, with pass criteria agreed in advance: your parts, the rate, every changeover, every E-stop and guard door. IEC 62381 defines FAT and SAT for process automation, and the idea carries over to robot cells. Our cells are run off in our Fontana shop before they ship, then commissioned on yours.
Commissioning and site acceptance test (SAT)
Commissioning brings the installed cell up on your floor: utilities connected, safety devices tested, signals checked against the machines on either side, robot points touched up. The SAT then repeats the key FAT checks there. Our FAT and SAT guide has a checklist for each, and how we work covers our run-off and commissioning steps.
Machine tending and lights-out operation
Machine tending is a robot loading and unloading a machine such as a lathe, mill or press. Lights-out means running with nobody there, overnight or through a weekend. In one machine tending cell we built, a robot moves parts from a Swiss lathe into a heater and a second robot places them into a forge. The cell supports lights-out operation.
Robot safety terms
These explain what the standards ask for and are not a sign-off for any cell. We do a risk assessment for each cell we build, and your own safety professional should review the design.
Risk assessment
A written review of every task people do at the cell, from loading and clearing jams to teaching and maintenance, with each task’s hazards and how they are reduced. The guarding follows from it. A3’s technical report RIA TR R15.306-2016 describes a task-based method, and our robot risk assessment guide walks through it step by step.
ANSI/A3 R15.06-2025
The US industrial robot safety standard, published by A3 in 2025 to replace the 2012 edition. Parts 1 and 2 adopt ISO 10218-1:2025 and ISO 10218-2:2025, covering the robot and the robot cell, and Part 3 (ANSI/A3 R15.06-3-2025) covers companies that use robot cells. Our robot safety standards guide goes through what changed.
Guarding and interlocks
Guarding is the fence, panels and doors that keep people out of the robot’s reach. An interlock is a switch that stops the robot safely when a door or gate opens. ISO 13857 ties fence height and opening size to the distance from the hazard. See robot cell guarding.
Light curtain and area scanner
A light curtain is a row of infrared beams across an opening, such as a load station. Break a beam and the robot stops. An area scanner is a safety laser scanner that watches a zone of floor and slows or stops the robot when someone walks in. The LR Mate assembly tables mentioned above are interlocked and light-curtained. Light curtain vs area scanner compares the two.
Safety distance
How far a light curtain, scanner field or guard opening has to sit from the hazard, so the robot has stopped before a person can reach it. It depends on how fast a person approaches, how long the system takes to stop, and how far a hand or body can reach in before the device detects it. ISO 13855:2024 gives the method. Our cell layout guide shows how it shapes the floor plan.
Lockout/tagout (LOTO)
Shutting off and locking out electrical, pneumatic and stored energy before anyone works inside the cell. In the US the rule is OSHA’s 29 CFR 1910.147. Lockout points work best when they are planned into the cell design.
Robot and end-of-arm tooling terms
| Robot type | How it moves | Typical jobs |
|---|---|---|
| Six-axis (articulated) | Six rotary joints, much like a shoulder, elbow and wrist | Palletizing, machine tending, welding, assembly, heavy parts |
| Delta | Parallel arms hung from an overhead base, meeting at one light platform | Fast, light picks off a conveyor, often food |
| SCARA | A horizontal arm with a vertical stroke at the end | Small-part assembly on a flat table |
We integrate FANUC robots only, and our cells have used everything from the LR Mate and FANUC delta robots up to the larger FANUC arms on our palletizing cells. Delta vs SCARA vs 6-axis covers how to choose, and our guide to FANUC robot models compares the families by payload and reach.
Payload
The weight the robot is rated to carry at the wrist, gripper and part together. The FANUC controller also stores the tool’s mass and center of gravity in a payload setting, which should be updated whenever the tool changes.
Wrist moment and inertia
How hard a load works the wrist axes, which depends on where its weight sits as well as how much there is. For a six-axis arm, FANUC’s spec sheet lists the allowable moment and inertia for the wrist axes, J4, J5 and J6. A long tool can exceed them on a robot whose payload looks fine, so check the tool’s weight and center of gravity against those limits before the robot is chosen.
Repeatability and accuracy
Repeatability is how closely a robot returns to a point it was taught. Accuracy is how closely it reaches a point given as a coordinate, such as a hole location from a CAD model. ISO 9283 treats them as separate characteristics. Jobs built on taught points depend mostly on repeatability, while CAD-driven jobs like robotic drilling and milling need a calibration step to close the gap.
End-of-arm tooling (EOAT)
Whatever mounts on the robot’s wrist to do the job: vacuum cups, gripper fingers, a weld torch, a spindle. ISO 8373 calls it an end effector, and OSHA’s technical manual notes the two names mean the same thing. EOAT is usually designed around one part, so it is the piece of a cell most likely to change, which is why we design and machine our own.
Vacuum and mechanical grippers
A vacuum gripper holds the part with suction cups and suits flat surfaces that seal, like cases, panels and trays. A mechanical gripper closes fingers on the part, usually machined to fit it. Soft-touch grippers use flexible fingers for product that marks easily, like raw dough. See vacuum vs mechanical grippers.
Bowl feeder
A vibrating bowl that sorts loose parts and delivers them one at a time, all facing the same way, to where the robot picks. On the spray nozzle assembly cells we built, bowl feeders present parts to the LR Mate robots nonstop.
FANUC terms: controller, UFRAME, UTOOL and programs
Robot terminology varies from one maker to the next. These are FANUC’s names, the ones you’ll hear at the teach pendant.
R-30iB controller
The controller is the cabinet that holds the robot’s servo drives, safety circuits and computer. R-30iB is one generation of FANUC controller, and a name you’ll see on many cabinets and quotes.
Teach pendant
The handheld unit, on a cable from the controller, used to jog the robot, teach points and edit programs. It has its own E-stop and a three-position enabling switch that must be held for the robot to move while teaching.
TP program and KAREL
A TP program is the everyday FANUC robot program, written line by line on the teach pendant: motion, I/O, registers and calls to other programs. KAREL is FANUC’s compiled, Pascal-like language for logic that is awkward in TP. Our FANUC robot programming page covers how we program the cells we build.
UFRAME (user frame)
A coordinate system taught on a fixture, table or pallet, so points are stored relative to the work instead of the robot. The usual three-point method touches the tool tip to an origin, a point along X and a point in the XY plane. If the fixture moves, you reteach the frame, not every point. User frames are measured from the world frame, which is fixed to the robot, and UFRAME 0 is the world frame itself.
UTOOL (tool frame) and TCP
The tool frame puts the robot’s working point, the tool center point (TCP), at the business end of the tool instead of the faceplate: the face of a vacuum cup, the tip of a torch or cutter. With a good TCP the robot can turn the tool around its tip while the tip stays put. FANUC’s three-point method teaches the TCP position by touching one fixed point from several wrist angles, and the six-point method adds the tool’s direction. UTOOL 0 is the bare faceplate. When a gripper is rebuilt, reteach the tool frame and the programs that use it follow.
Dual Check Safety (DCS)
FANUC controller software that monitors the robot’s position and speed with redundant processors and removes motor power if the robot passes a programmed limit. It can keep the arm out of a zone or cap its speed without external sensors. The Basic Position Check option restricts the arm to set zones, and Position and Speed Check also enforces speed limits. DCS settings are part of the safety design, so they come out of the risk assessment and get tested at the run-off.
FANUC vision and conveyor tracking terms
iRVision
FANUC’s machine vision, built into the robot controller, so there is no separate vision PC. In 2D it finds a part’s position and rotation, and with 3D sensors it adds height and tilt. The camera can be fixed over the work or mounted on the arm, and we have built vision-guided cells both ways. 2D vs 3D robot vision explains which one a part needs.
Vision calibration
Tying what the camera sees to the robot’s coordinates, so a part found in the image becomes a point the robot can reach. With iRVision it is usually done with a calibration grid, and it has to be redone if the camera, lens or mount moves. Our iRVision calibration guide walks through it.
Conveyor tracking (line tracking)
The robot follows a moving belt and picks or places parts without stopping it. An encoder on the conveyor sends pulses as the belt moves, and the encoder scale, in counts per millimeter, turns them into distance. The robot then meets each part where it is now, not where the camera saw it.
Tracking frame and boundaries
The tracking frame is taught on the belt, much like a user frame, with X pointing in the direction of travel. The upstream and downstream boundaries mark the stretch of belt where each robot may pick.
iRPickTool
FANUC software for picking and placing on moving conveyors. It handles line tracking on linear and circular conveyors, tray setups and load balancing across several robots, and works with iRVision to find parts. Our iRPickTool line tracking guide explains it from a working line.
Load balancing
Splitting the parts on one belt between two or more robots, so none falls behind and no part gets picked twice. On our twin-delta tray loading line, each robot tracks the belt with its own encoder and both controllers hold the full line map.
Stack pattern
The layout of a pallet: where each case sits in a layer, which way it faces, and how many layers go on. The palletizing cells we built in Temecula place every case to the stack pattern, layer by layer. FANUC palletizing programming covers how patterns are set up.
Controls and software terms
PLC
Programmable logic controller, the industrial computer that sequences the cell and talks to the robot, conveyors, sensors and neighboring machines. E-stops, interlocks and light curtains usually run through a safety relay or safety PLC rated for the job. We write PLC and safety logic for Allen-Bradley and Siemens in-house.
HMI
Human-machine interface, the operator’s screen for running the cell, reading faults and switching products. The custom HMI on our LR Mate assembly cells was written for the customer’s crew and shows cycle times for each table, color changeover and fault status.
I/O and handshake
Inputs and outputs are the signals between the robot, the PLC and other machines, like part present or gripper closed. A handshake is the agreed exchange of those signals when two machines hand work to each other.
Control panel
The enclosure that holds the PLC, safety devices, power distribution and terminals for the cell. NFPA 79 is the electrical standard for industrial machinery, and UL 508A covers industrial control panels. If your plant needs a listed panel, say so in the RFQ. We build, wire and test our control panels in our own shop.
ERP integration
Connecting the cell to the business system, so counts, jobs and scrap post automatically instead of being keyed in. We write custom Python that ties machines to the ERP. See machine data and ERP integration.
If a term you need is missing, or one here doesn’t match what you see on your own floor, tell us and we’ll add it.
Sources
- ISO 8373:2021, Robotics: Vocabulary
- OSHA Technical Manual, Section IV Chapter 4: Industrial robot systems and industrial robot system safety
- ISO 9283:1998, Manipulating industrial robots: performance criteria and related test methods
- IEC 62381:2024, Automation systems in the process industry: factory acceptance test (FAT), site acceptance test (SAT) and site integration test (SIT)
- A3: New ANSI/A3 R15.06-2025 American National Standard for Industrial Robot Safety
- ISHN: Part 3 of ANSI/A3 R15.06-2025 robot safety standard now available
- A3 Store: RIA TR R15.306-2016, Task-based risk assessment methodology
- ISO 13857:2019, Safety distances to prevent hazard zones being reached by upper and lower limbs
- ISO 13855:2024, Safety of machinery: positioning of safeguards with respect to the approach of the human body
- Banner Engineering: Safety distance formulas, ANSI B11.19-2019 and EN ISO 13855:2024 (PDF)
- OSHA 29 CFR 1910.147, The control of hazardous energy (lockout/tagout)
- FANUC America: M-20iD/25 specifications (payload, allowable wrist moment and inertia)
- FANUC Tech Transfer: FANUC user tool setup tips
- FANUC America: Dual Check Safety (DCS)
- FANUC America: iRVision robotic vision systems
- FANUC America: iRPickTool line tracking software
- NFPA 79, Electrical Standard for Industrial Machinery
- UL Solutions: Industrial control panels and the panel shop program